China Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ) - China Supplier
China Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ) - China Supplier China Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ) - China Supplier China Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ) - China Supplier China Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ) - China Supplier China Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ) - China Supplier

Communication Fiber Optic Cable Positioning Nail-Shaped Electronic Marker ED1000-XR (101.4KHZ)

Price:Negotiable
Industry Category: Telecommunications
Product Category:
Brand: 华翔天诚
Spec: ED1000-XR(101.4KHZ)


Contact Info
  • Add:龙岗区南湾街道沙坪路111号吉茂大厦5016, Zip:
  • Contact: 戴先生
  • Tel:13823276735
  • Email:dzh0809@163.com

Other Products

Description
Additional Information

Communication Fiber Optic Cable Positioning Nail-shaped Electronic Marker ED1000-XR (101.4KHZ) adopts a nail-shaped structure, typically used for supplementary marking of already buried pipelines or underground facilities, or for ground-level supplementary marking of pipelines where excavation is inconvenient. For newly installed shallow-buried underground facilities or pipelines, it can also be installed alongside these underground facilities or pipelines.

Communication Fiber Optic Cable Positioning Nail-shaped Electronic Marker ED1000-XR (101.4KHZ) is designed and manufactured according to international standard frequencies, compatible with electronic marker detectors also designed and produced based on international standard frequencies (in no-ID mode). The ED1100 can also be configured with RFID chips supporting both ASK and FSK modulation modes, turning it into an electronic information marker. Through the ID number in the marker, ground detection personnel can clearly confirm that what they have found is the marker pre-buried by the user unit, without suspecting interference signals or markers buried by other units. For ID markers, after obtaining the ID number, ground detection personnel can search for related information of the marked object (such as type, specifications, pre-backfill photos, etc.) stored in the cloud database via the ID number, enabling visual management of underground pipelines or facilities.

The ED1100-ID-RW marker, equipped with an FSK RFID chip, also supports directly writing simple information like the type and specifications of the marked object into the internal chip of the marker using the ED8000 V400 detector before backfilling. This provides a more direct information management solution for remote areas with poor wireless signals or user units that cannot upload marked object information to the cloud due to information security concerns.

1. Basic Specifications and Parameters

 HDPE encapsulation, resistant to chemical corrosion

 Diameter: 20mm

 Length: 76mm

 Weight: 0.03kg ±10%

 Operating temperature: -20℃ to 50℃ 

 Storage temperature: -20℃ to 70℃

 Drop test: Can withstand falling from a height of 10 feet (about 3 meters) onto concrete ground

 Operating frequency (customizable):

    Electric power 169.8Khz

    Water supply 145.7 Khz

    Drainage 121.6 Khz

    Communication 101.4 Khz

    Gas 83 |87Khz

   General (China) 134 Khz

2. Detection Related Parameters

Parameter

Product Model

ED1100-XR

ED1100-ID-R

ED1100-ID-RW

Maximum detectable depth without ID

0.7~1.0 meters

0.7~1.0 meters

0.8~1.2 meters

Maximum ID reading depth

Not supported

0.7~1.0 meters

0.8~1.2 meters

Maximum marker information writing depth

Not supported

Not supported

0<0.3 meters

ID number format

Not supported

3-digit manufacturer code + 10-digit ID number

3-digit customer code + 10-digit ID number

Writable information content

Not supported

Not supported

Type and specifications of the marked object

3. Installation Instructions

During installation, use an impact drill to bore a hole in the concrete or asphalt pavement above the underground pipeline, insert the nail marker into the hole, and then seal the hole with cement or asphalt.

Install vertically along the path at intervals of 10-20m based on importance, with a burial depth not exceeding 0.6m, a minimum horizontal distance of 2.5cm from the marked object, and a minimum spacing of 1m between two adjacent markers.

Step 1: Determine the pipeline location and set the marker position

Step 2: Use a drilling machine to create a hole 10~50cm deep, then place the marker inside

Step 3: Seal the drilled hole with cement

Industry Category Telecommunications
Product Category
Brand: 华翔天诚
Spec: ED1000-XR(101.4KHZ)
Stock: 10000
Manufacturer:
Origin: China / Guangdong / Shenshi
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192